Design Number: Minimum "C-H" Shaped Stud Size: Min. Thickness: Fire Resistance Ratings
U428 2-1/2" C-H Shaped Studs, 1-1/2" flange 25 GA. 2 hour
U429 2-1/2" C-H Shaped Studs, 1-1/2" flange 25 GA. 2 hour
U438 2 1/2" C-H Shaped studs,  1 1/2" flange 25 GA. * 2 hour
U459 2 1/2" C-H Shaped studs,  1 1/2" flange 20 GA. 2 hour
U467 2 1/2" C-H Shaped studs,  1 1/2" flange 25 GA. * 2 hour
U469 2 1/2" C-H Shaped studs,  1 1/2" flange 25 GA. * 1 hour
U492 4" C-H Shaped studs,  1 1/2" flange 25 GA. 2 hour
* - Minimum thickness depends on manufacturer of drywall.
1) Steeler C-H Studs conform to the manufacturers standard gauge (MSG), shape, and section property specifications listed in each UL/USG system design and Fire Resistance Rating and are therefore acceptable for use with listed wallboard gypsum products bearing the UL classification marking.
2) The 2 1/2" web X 1 1/2" flange dimension for C-H Studs is a minimum requirement and larger sizes, i.e.; 4" and 6" (studs) are permitted system stud sizes under any UL certification.  
3) All wallboard sizes specified in each system design must bear a UL classification marking.
4) Note specific manufacturers standard gauge (MSG) and stud length (floor to ceiling) requirements in each system design.
5) Note "J" shaped floor and ceiling runners (J Track) require unequal leg lengths of 1 in. and 2 in. and manufacturers standard gauge (MSG) requirements may vary by system design.
Steeler Part #: Stud Dimensions: Gauge:
0250H150-018 2 1/2" x 1 1/2" deep 25
0250H150-030 2 1/2" x 1 1/2" deep 20DW
0250H150-033 2 1/2" x 1 1/2" deep 20
0400H150-018 4" x 1 1/2" deep 25
0400H150-030 4" x 1 1/2" deep 20DW
0400H150-033 4" x 1 1/2" deep 20
0600H150-018 6" x 1 1/2" deep 25
0600H150-030 6" x 1 1/2" deep 20DW
0600H150-033 6" x 1 1/2" deep 20    
   
References:
UL Technical Services, Conformity Assessment Services (CAS)
Phone Number: (847) 272-8800 ext. 42364; Fax (847) 509-6292.
http://www.ul.com/contact.html
David Jeter, Steeler Engineer.
Phone Number: (800) 275-2279; Fax (206) 725-1300.
10023 Martin Luther King Jr. Way South, Seattle, WA 98178
www.steeler.com    e-mail: engineering@steeler.com
To view the engineering data calculations for each size & gauge click on the links at the bottom of the browser for the different pages of the catalog.
For a hard copy of this catalog please e-mail or call today.
Steeler and Steeler, Inc. are registered trademarks of Steeler, Inc. Copyright 2004 Steeler Inc. All Rights Reserved. Rev. 1.1 December 7, 2004
`