| STEELER® INC. |
|
|
| SLOTTED STUD™ |
|
| 1-800-275-2279 |
|
|
|
|
|
| The STEELER® SLOTTED STUD™ is an innovative and economical light gauge steel framing
Deflection Head-Of-Wall (HW) System which revolutionizes commercial and
residential construction techniques.
The STEELER® SLOTTED STUD™ is classified by Underwriters
Laboratories, Inc. for 500 successful cycles. It is unlike any other head-of-wall
assembly currently in the construction industry and can be used for both
non-load bearing and wind load-bearing walls. The STEELER® SLOTTED STUD™ has a slot of 2-1/4" which allows for up to a 2"
deflection depending on which Head-Of-Wall System is used. The Engineer of Record shall specify which
Head-Of-Wall System to use. |
|
|
|
|
|
|
|
|
|
| UL® Head of Wall
Systems: (Click on HW-D System Number for UL Head-Of-Wall Information) |
|
|
System Number: |
Fire Rating: |
|
Movement Class &
Capabilities: |
|
|
HW-D-0016 |
1 & 2 Hour Fire
Rating |
Classes II & III, 25%
Compression |
|
|
|
HW-D-0020 |
1 & 2 Hour Fire
Rating |
Class II, 25% Compression
or Extension |
|
|
HW-D-0021 |
1 & 2 Hour Fire
Rating |
Class II, 18.75%
Compression and Extension |
|
|
HW-D-0029 |
1 & 2 Hour Fire
Rating |
Class II, 25% Compression
or Extension |
|
|
|
HW-D-0032 |
2 Hour Fire Rating |
|
Class II, 50% Compression
or Extension |
|
|
HW-D-0033 |
2 Hour Fire Rating |
|
Class II, 50% Compression
or Extension |
|
|
HW-D-0034 |
1 & 2 Hour Fire
Rating |
Class II, 25% Compression
or Extension |
|
|
HW-D-0037 |
2 Hour Fire Rating |
|
Class II, 18.75%
Compression or Extension |
|
|
HW-D-0048 |
1 & 2 Hour Fire
Rating |
Class II, 33% Compression
or Extension |
|
|
HW-D-0049 |
1 & 2 Hour Fire
Rating |
Class II, 50% Compression
or Extension |
|
|
|
|
|
|
|
|
|
|
STEELER® INC. SLOTTED STUD™ |
|
|
|
LIGHT GAUGE FRAMING |
|
|
|
FOR USE IN JOINT SYSTEMS |
|
|
|
U.L. Classified
XHLI.R21503 |
|
|
|
U.L. Classified for
Canada XHLI7.21503 |
|
|
|
CSFM Fire Engineering
Listed 8-13-04 |
|
|
| For questions or
additional information, please contact our Marketing Department. |
|
| STEELER® INC. Corporate Headquarters |
|
| 1-800-275-2279 Toll
Free |
|
| 206-725-2500 Local |
|
|
|
| 206-725-1700
Marketing Fax |
|
|
|
| 10023 Martin
Luther King Jr. Way South |
|
| Seattle, WA 98178 |
|
| e-mail:
marketing@steeler.com |
|
|
|
| For technical
questions, please visit our website at www.steeler.com |
|
| or contact David Jeter PE SE, Manager, Steeler
Engineering Department |
|
| email: engineering@steeler.com |
|
| U.S. Patent No.
6,854,237 |
|
| Steeler
and Steeler, Inc. are registered trademarks of Steeler, Inc. Copyright 2005
Steeler Inc. All Rights Reserved. |
Rev 1.5 |
|